三相立式线性调(Ⅰ、Ⅰ△)管形(G)分接开关(250~1000A)
THREE-PHASE LINEAR VOLTAGE-REGULATING(Ⅰ、Ⅰ△)PIPE-FORM(G)VERTICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer
|
额定电流 (A)
Rated current
|
额定电压 (kV)
Rated voltage
|
分接位置数
Tap position number
|
安装尺寸(mm)
Install dimension (mm)
|
H |
H1 |
H2 |
H3 |
Φd1 |
Φd2 |
WSGⅠ250~1000/35-3×3 |
250
400
500
630
800
1000
|
35 |
3 |
320 |
235 |
1150 |
1250 |
176 |
190 |
WSGⅠ△250~1000/35-3×3 |
WSGⅠ250~1000/35-5×5 |
5 |
320 |
235 |
1150 |
1250 |
WSGⅠ△250~1000/35-5×5 |
WSGⅠ250~1000/110-3×3 |
110 |
3 |
320 |
235 |
1150 |
1450 |
WSGⅠ△250~1000/110-3×3 |
500 |
235 |
1500 |
1800 |
WSGⅠ250~1000/110-5×5 |
5 |
320 |
235 |
1150 |
1450 |
216 |
230 |
WSGⅠ△250~1000/110-5×5 |
500 |
235 |
1500 |
1800 |
注:1、开关相别由用户定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
三相立式线性调(Ⅰ、Ⅰ△)管形(G)分接开关(1250~1600A)
THREE-PHASE LINEAR VOLTAGE-REGULATING(Ⅰ、Ⅰ△)PIPE-FORM(G)VERTICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer
|
额定电流 (A)
Rated current
|
额定电压 (kV)
Rated voltage
|
分接位置数
Tap position number
|
安装尺寸(mm)
Install dimension (mm)
|
H |
H1 |
H2 |
H3 |
H4 |
Φd1 |
Φd2 |
WSGⅠ1250~1600/35-3×3 |
1250
1600 |
35 |
3 |
400 |
350 |
150 |
1400 |
1500 |
196 |
210 |
WSGⅠ△1250~1600/35-3×3 |
WSGⅠ1250~1600/35-5×5 |
5 |
400 |
350 |
150 |
1400 |
1500 |
196 |
210 |
WSGⅠ△1250~1600/35-5×5 |
WSGⅠ1250~1600/110-3×3 |
110 |
3 |
400 |
350 |
150 |
1400 |
1700 |
196 |
210 |
WSGⅠ△1250~1600/110-3×3 |
600 |
350 |
150 |
1800 |
- |
WSGⅠ1250~1600/110-5×5 |
5 |
400 |
350 |
150 |
1400 |
1700 |
226 |
240 |
WSGⅠ△1250~1600/110-5×5 |
600 |
350 |
150 |
1800 |
- |
注:1、开关相别由用户确定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
“1+2”相立式线性调((Ⅰ、Ⅰ△)管形(G)分接开关(250~1000A)
“1+2”PHASE LINEAR VOLTAGE-REGULATING(Ⅰ、Ⅰ△)PIPE-FORM(G)VERTICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer
|
额定电流 (A)
Rated current
|
额定电压 (kV)
Rated voltage
|
分接位置数
Tap position number
|
安装尺寸(mm)
Install dimension (mm)
|
H |
H1 |
H2 |
Φd1 |
Φd2 |
WDGⅠ250~1000/35-3×3 |
250
400
500
630
800
1000 |
35 |
3 |
— |
— |
— |
176 |
190 |
WLGⅠ250~1000/35-3×3 |
320 |
235 |
830 |
WDGⅠ△250~1000/35-3×3 |
— |
— |
— |
WLGⅠ△250~1000/35-3×3 |
320 |
235 |
830 |
WDGⅠ250~1000/35-5×5 |
5 |
— |
— |
— |
176 |
190 |
WLGⅠ250~1000/35-5×5 |
320 |
235 |
830 |
WDGⅠ△250~1000/35-5×5 |
— |
— |
— |
WLGⅠ△250~1000/35-5×5 |
320 |
235 |
830 |
WDGⅠ250~1000/110-3×3 |
110 |
3 |
— |
— |
— |
176 |
190 |
WLGⅠ250~1000/110-3×3 |
320 |
235 |
830 |
WDGⅠ△250~1000/110-3×3 |
— |
— |
— |
WLGⅠ△250~1000/110-3×3 |
500 |
235 |
1000 |
WDGⅠ250~1000/110-5×5 |
5 |
— |
— |
— |
216 |
230 |
WLGⅠ250~1000/110-5×5 |
320 |
235 |
830 |
WDGⅠ△250~1000/110-5×5 |
— |
— |
— |
WLGⅠ△250~1000/110-5×5 |
500 |
235 |
1000 |
注:1、开关相别由用户确定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
“1+2”相立式线性调((Ⅰ、Ⅰ△)管形(G)分接开关(1250~1600A)
“1+2”PHASE LINEAR VOLTAGE-REGULATING(Ⅰ、Ⅰ△)PIPE-FORM(G)VERTICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer
|
额定电流 (A)
Rated current
|
额定电压 (kV)
Rated voltage
|
分接位置数
Tap position number
|
安装尺寸(mm)
Install dimension (mm)
|
H |
H1 |
H2 |
H3 |
Φd1 |
Φd2 |
WDGⅠ1250~1600/35-3×3 |
1250
1600 |
35 |
3 |
— |
— |
— |
— |
196 |
210 |
WLGⅠ1250~1600/35-3×3 |
400 |
350 |
150 |
1000 |
WDGⅠ△1250~1600/35-3×3 |
— |
— |
— |
— |
WLGⅠ△1250~1600/35-3×3 |
400 |
350 |
150 |
1000 |
WDGⅠ1250~1600/35-5×5 |
5 |
— |
— |
— |
— |
196 |
210 |
WLGⅠ1250~1600/35-5×5 |
400 |
350 |
150 |
1000 |
WDGⅠ△1250~1600/35-5×5 |
— |
— |
— |
— |
WLGⅠ△1250~1600/35-5×5 |
400 |
350 |
150 |
1000 |
WDGⅠ1250~1600/110-3×3 |
110 |
3 |
— |
— |
— |
— |
196 |
210 |
WLGⅠ1250~1600/110-3×3 |
400 |
350 |
150 |
1000 |
WDGⅠ△1250~1600/110-3×3 |
— |
— |
— |
— |
WLGⅠ△1250~1600/110-3×3 |
600 |
350 |
150 |
1200 |
WDGⅠ1250~1600/110-5×5 |
5 |
— |
— |
— |
— |
226 |
240 |
WLGⅠ1250~1600/110-5×5 |
400 |
350 |
150 |
1000 |
WDGⅠ△1250~1600/110-5×5 |
— |
— |
— |
— |
WLGⅠ△1250~1600/110-5×5 |
600 |
350 |
150 |
1200 |
注:1、开关相别由用户确定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
三相卧式(W)线性调(Ⅰ、Ⅰ△)管形(G)分接开关(250~1000A)
THREE-PHASES LINKAGE SINGLE-BRIDGE CROSSING CONNCTION(Ⅰ、Ⅰ△)PIPE-FORM(G) HORIZINTAL(W) TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer
|
额定电流 (A)
Rated current
|
额定电压 (kV)
Rated voltage
|
分接位置数
Tap position number
|
安装尺寸(mm)
Install dimension (mm)
|
L |
L1 |
L2 |
L3 |
L4 |
B |
H |
H1 |
Φd1 |
Φd2 |
WSGⅠ250~1000/35-3×3W |
250
400
500
630
800
1000 |
35 |
3 |
320 |
235 |
1100 |
500 |
570 |
250 |
200 |
350 |
176 |
190 |
WSGⅠ△250~1000/35-3×3W |
WSGⅠ250~1000/35-5×5 W |
5 |
320 |
235 |
1100 |
500 |
570 |
250 |
200 |
350 |
176 |
190 |
WSGⅠ△250~1000/35-5×5 W |
WSGⅠ250~1000/110-3×3 W |
110 |
3 |
320 |
235 |
1100 |
500 |
570 |
250 |
280 |
430 |
176 |
190 |
WSGⅠ△250~1000/110-3×3 W |
500 |
285 |
1550 |
640 |
880 |
WSGⅠ250~1000/110-5×5 W |
5 |
320 |
235 |
1100 |
500 |
570 |
300 |
300 |
470 |
216 |
230 |
WSGⅠ△250~1000/110-5×5 W |
500 |
285 |
1550 |
640 |
880 |
注:1、开关相别由用户确定。
三相卧式(W)线性调(Ⅰ、Ⅰ△)管形(G)分接开关(1250~1600A)
THREE-PHASES LINKAGE SINGLE-BRIDGE CROSSING CONNCTION(Ⅰ、Ⅰ△)PIPE-FORM(G) HORIZINTAL(W) TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer |
额定电流 (A)
Rated current |
额定电压 (kV)
Rated voltage |
分接位置数
Tap position number |
安装尺寸(mm)
Install dimension (mm) |
L |
L1 |
L2 |
L3 |
L4 |
L5 |
B |
H |
H1 |
Φd1 |
Φd2 |
WSGⅠ1250~1600/35-3×3W |
1250
1600 |
35 |
3 |
400 |
350 |
150 |
1400 |
655 |
715 |
270 |
210 |
370 |
196 |
210 |
WSGⅠ△1250~1600/35-3×3W |
WSGⅠ1250~1600/35-5×5W |
5 |
400 |
350 |
150 |
1400 |
655 |
715 |
270 |
210 |
370 |
196 |
210 |
WSGⅠ△1250~1600/35-5×5W |
WSGⅠ1250~1600/110-3×3W |
110 |
3 |
400 |
350 |
150 |
1400 |
655 |
715 |
270 |
300 |
460 |
196 |
210 |
WSGⅠ△1250~1600/110-3×3W |
600 |
400 |
150 |
1850 |
805 |
1015 |
WSGⅠ1250~1600/110-5×5W |
5 |
400 |
350 |
150 |
1400 |
655 |
715 |
300 |
320 |
500 |
226 |
240 |
WSGⅠ△1250~1600/110-5×5W |
600 |
400 |
150 |
1850 |
805 |
1015 |
注:1、开关相别由用户确定。
|