三相立式正反调(Ⅶ、Ⅶ△)管形(G)分接开关(250~800A)
THREE-PHASES POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ、Ⅶ△)PIPE-FORM (G)VERICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号 |
额定电流 (A) |
额定电压 (kV) |
分接位置数 |
安装尺寸(mm) |
H |
H1 |
H2 |
H3 |
H4 |
Φd1 |
Φd2 |
WSGⅦ250~630/35-3×3
WSGⅦ250~630/35-4×5
WSGⅦ250~630/35-5×7
|
250
400
500
630 |
35 |
3、5
7 |
285 |
265 |
150 |
1500 |
1600 |
196 |
210 |
WSGⅦ△250~630/35-3×3
WSGⅦ△250~630/35-4×5
WSGⅦ△250~630/35-5×7
|
WSGⅦ250~630/110-3×3
WSGⅦ250~630/110-4×5
WSGⅦ250~630/110-5×7
|
110 |
1700 |
WSGⅦ△250~630/110-3×3
WSGⅦ△250~630/110-4×5
WSGⅦ△250~630/110-5×7
|
380 |
265 |
150 |
1700 |
1950 |
WSGⅦ800/35-3×3
WSGⅦ800/35-4×5
WSGⅦ800/35-5×7
|
800 |
35 |
275 |
260 |
160 |
1500 |
1600 |
WSGⅦ△800/35-3×3
WSGⅦ△800/35-4×5
WSGⅦ△800/35-5×7
|
WSGⅦ800/110-3×3
WSGⅦ800/110-4×5
WSGⅦ800/110-5×7
|
110 |
1700 |
WSGⅦ△800/110-3×3
WSGⅦ△800/110-4×5
WSGⅦ△800/110-5×7
|
425 |
285 |
160 |
1835 |
— |
注:1、开关的相别由用户定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
三相立式正反调(Ⅶ)管形(G)分接开关(1000~2000A)
THREE-PHASES POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ)PIPE-FORM (G)VERICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号 |
额定电流 (A) |
额定电压 (kV) |
分接位置数 |
安装尺寸(mm) |
H |
H1 |
H2 |
H3 |
H4 |
Φd1 |
Φd2 |
WSGⅦ1000~1250/35-3×3~4×5
WSGⅦ1000~1250/35-5×7
|
1000
1250 |
35 |
3、5
7 |
300 |
275 |
220 |
1770 |
1850 |
246 |
260 |
WSGⅦ△1000~1250/35-3×3~4×5
WSGⅦ△1000~1250/35-5×7
|
WSGⅦ1000~1250/110-3×3~4×5
WSGⅦ1000~1250/110-5×7
|
110 |
1900 |
WSGⅦ△1000~1250/110-3×3~4×5
WSGⅦ△1000~1250/110-5×7
|
400 |
275 |
220 |
1970 |
— |
WSGⅦ1600/35-3×3
WSGⅦ1600/35-4×5
WSGⅦ1600/35-5×7
|
1600
|
35 |
330 |
275 |
220 |
1850 |
1930 |
WSGⅦ△1600/35-3×3
WSGⅦ△1600/35-4×5
WSGⅦ△1600/35-5×7
|
WSGⅦ1600/110-3×3
WSGⅦ1600/110-4×5
WSGⅦ1600/110-5×7
|
110 |
1980 |
WSGⅦ2000/35-4×5 |
2000 |
35 |
340 |
275 |
260 |
2000 |
2090 |
WSGⅦ△2000/35-4×5 |
注:1、开关的相别由用户定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
“1+2”相立式正反调(Ⅶ)管形(G)分接开关(250~800A)
“1+2”PHASE POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ)PIPE-FORM (G)VERICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号 |
额定电流 (A) |
额定电压(kV) |
分接位置数 |
安装尺寸(mm) |
H |
H1 |
H2 |
H3 |
Φd1 |
Φd2 |
WDGⅦ250~630/35-3×3~4×5
WDGⅦ250~630/35-5×7
|
250
400
500
630 |
35 |
3、5
7
|
— |
265 |
150 |
680 |
196 |
210 |
WLGⅦ250~630/35-3×3~4×5
WLGⅦ250~630/35-5×7
|
285 |
265 |
150 |
1065 |
WDGⅦ△250~630/35-3×3~4×5
WDGⅦ△250~630/35-5×7
|
— |
265 |
150 |
680 |
WLGⅦ△250~630/35-3×3~4×5
WLGⅦ△250~630/35-5×7
|
285 |
265 |
150 |
1065 |
WDGⅦ250~630/110-3×3~4×5
WDGⅦ250~630/110-5×7
|
110 |
— |
265 |
150 |
680 |
WLGⅦ250~630/110-3×3~4×5
WLGⅦ250~630/110-5×7
|
285 |
265 |
150 |
1065 |
WDGⅦ△250~630/110-3×3~4×5
WDGⅦ△250~630/110-5×7
|
— |
265 |
150 |
680 |
WLGⅦ△250~630/110-3×3~4×5
WLGⅦ△250~630/110-5×7
|
380 |
265 |
150 |
1170 |
WDGⅦ800/35-3×3~4×5
WDGⅦ800/35-5×7
|
800
|
35 |
_— |
285 |
160 |
680 |
WLGⅦ800/35-3×3~4×5
WLGⅦ800/35-5×7
|
275 |
260 |
160 |
1065 |
WDGⅦ△800/35-3×3~4×5
WDGⅦ△800/35-5×7
|
_— |
285 |
160 |
680 |
WLGⅦ△800/35-3×3~4×5
WLGⅦ△800/35-5×7
|
275 |
260 |
160 |
1065 |
WDGⅦ800/110-3×3~4×5
WDGⅦ800/110-5×7
|
110 |
_— |
285 |
160 |
680 |
WLGⅦ800/110-3×3~4×5
WLGⅦ800/110-5×7
|
275 |
260 |
160 |
1065 |
WDGⅦ△800/110-3×3~4×5
WDGⅦ△800/110-5×7
|
_— |
285 |
160 |
680 |
WLGⅦ△800/110-3×3~4×5
WLGⅦ△800/110-5×7
|
425 |
285 |
160 |
1250 |
注:1、开关的相别由用户定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
“1+2”相立式正反调(Ⅶ)管形(G)分接开关(1000~2000A)
“1+2”PHASE POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ)PIPE-FORM (G)VERICAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号 |
额定电流 (A) |
额定电压 (kV) |
分接位置数 |
安装尺寸(mm) |
H |
H1 |
H2 |
H3 |
Φd1 |
Φd2 |
WDGⅦ1000~1250/35-3×3~4×5
WDGⅦ1000~1250/35-5×7 |
10001250 |
35 |
3、5
7 |
— |
275 |
220 |
750 |
246
|
260
|
WLGⅦ1000~1250/35-3×3~4×5
WLGⅦ1000~1250/35-5×7 |
300 |
275 |
220 |
1250 |
WDGⅦ△1000~1250/35-3×3~4×5
WDGⅦ△1000~1250/35-5×7 |
— |
275 |
220 |
750 |
WLGⅦ△1000~1250/35-3×3~4×5
WLGⅦ△1000~1250/35-5×7 |
300 |
275 |
220 |
1250 |
WDGⅦ1000~1250/110-3×3~4×5
WDGⅦ1000~1250/110-5×7 |
110 |
— |
275 |
220 |
750 |
WLGⅦ1000~1250/110-3×3~4×5
WLGⅦ1000~1250/110-5×7 |
300 |
275 |
220 |
1250 |
WDGⅦ△1000~1250/110-3×3~4×5
WDGⅦ△1000~1250/110-5×7 |
— |
275 |
220 |
750 |
WLGⅦ△1000~1250/110-3×3~4×5
WLGⅦ△1000~1250/110-5×7 |
400 |
275 |
220 |
1350 |
WDGⅦ1600/35-3×3~4×5
WDGⅦ1600/35-5×7 |
1600
|
35
|
— |
275 |
220 |
750 |
WLGⅦ1600/35-3×3~4×5
WLGⅦ1600/35-5×7 |
330 |
275 |
220 |
1300 |
WDGⅦ△1600/35-3×3~4×5
WDGⅦ△1600/35-5×7 |
— |
275 |
220 |
750 |
WLGⅦ△1600/35-3×3~4×5
WLGⅦ△1600/35-5×7 |
330 |
275 |
220 |
1300 |
WDGⅦ1600/110-3×3~4×5
WDGⅦ1600/110-5×7 |
110 |
— |
275 |
220 |
750 |
WLGⅦ1600/110-3×3~4×5
WLGⅦ1600/110-5×7 |
330 |
275 |
220 |
1300 |
WDGⅦ2000/35-3×3~4×5
WDGⅦ2000/35-5×7 |
2000 |
35 |
— |
275 |
260 |
800 |
WLGⅦ2000/35-3×3~4×5
WLGⅦ2000/35-5×7 |
340 |
275 |
260 |
1400 |
注:1、开关的相别由用户定;
2、用户选择落地安装时,请在开关型号后加D代号,以便区别。
三相卧式(W)正反调(Ⅶ、Ⅶ△)管形(G)分接开关(250~800A)
THREE-PHASES POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ、Ⅶ△)PIPE-FORM (G) HORIZONTAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer |
额定电流 (A)
Rated current |
额定电压 (kV)
Rated voltage |
分接位置数
Tap position number |
安装尺寸(mm)
Install dimension (mm)
|
L |
L1 |
L2 |
L3 |
L4 |
L5 |
B |
H |
H1 |
Φd1 |
Φd2 |
WSGⅦ250~630/35-3×3W
WSGⅦ250~630/35-4×5W
WSGⅦ250~630/35-5×7W
|
250
400
500
630 |
35 |
3、5、7 |
285 |
265 |
150 |
1500 |
662 |
808 |
270 |
210 |
370 |
196 |
210 |
WSGⅦ△250~630/35-3×3W
WSGⅦ△250~630/35-4×5W
WSGⅦ△250~630/35-5×7W
|
WSGⅦ250~630/110-3×3W
WSGⅦ250~630/110-4×5W
WSGⅦ250~630/110-5×7W
|
110 |
WSGⅦ△250~630/110-3×3W
WSGⅦ△250~630/110-4×5W
|
380 |
265 |
150 |
1700 |
710 |
960 |
270 |
300 |
460 |
WSGⅦ800/35-3×3W
WSGⅦ800/35-4×5W
WSGⅦ800/35-5×7W
|
800 |
35 |
275 |
260 |
160 |
1500 |
662 |
808 |
270 |
210 |
370 |
WSGⅦ△800/35-3×3W
WSGⅦ△800/35-4×5W
WSGⅦ△800/35-5×7W
|
WSGⅦ800/110-3×3W
WSGⅦ800/110-4×5W
WSGⅦ800/110-5×7W
|
110 |
WSGⅦ△800/110-3×3W
WSGⅦ△800/110-4×5W
WSGⅦ△800/110-5×7W
|
425 |
285 |
160 |
1835 |
763 |
1042 |
270 |
300 |
460 |
注:1、开关的相别由用户定.
三相卧式(W)正反调(Ⅶ、Ⅶ△)管形(G)分接开关(1000~2000A)
THREE-PHASES POSITIVE-NEGATIVE VOLTAGE-REGULATING(Ⅶ、Ⅶ△)PIPE-FORM (G) HORIZONTAL TAP-CHANGER
外形、安装尺寸图OUTLINE AND INSTALLATION SIZE DIAGRAM

开关型号、安装尺寸对照表
TYPE OF TAP CHANGER AND INSTALLATION SIZE CHART
开关型号
Type of tap changer |
额定电流 (A)
Rated current |
额定电压 (kV)
Rated voltage |
分接位置数
Tap position number |
安装尺寸(mm)
Install dimension (mm)
|
L |
L1 |
L2 |
L3 |
L4 |
L5 |
L6 |
B |
H |
H1 |
Φd1 |
Φd2 |
WSGⅦ1000~1250/35-3×3W
WSGⅦ1000~1250/35-4×5W
WSGⅦ1000~1250/35-5×7W |
1000
1250
|
35 |
3、5、7 |
300 |
275 |
220 |
1720 |
630 |
520 |
540 |
330 |
220 |
410 |
246 |
260 |
WSGⅦ△1000~1250/35-3×3W
WSGⅦ△1000~1250/35-4×5W
WSGⅦ△1000~1250/35-5×7W
|
WSGⅦ1000~1250/110-3×3W
WSGⅦ1000~1250/110-4×5W
WSGⅦ1000~1250/110-5×7W
|
110 |
250 |
440 |
WSGⅦ1600/35-3×3W
WSGⅦ1600/35-4×5W
WSGⅦ1600/35-5×7W
|
1600
|
35 |
330 |
275 |
220 |
1800 |
645 |
550 |
575 |
330 |
220 |
410 |
WSGⅦ△1600/35-3×3W
WSGⅦ△1600/35-4×5W
WSGⅦ△1600/35-5×7W
|
WSGⅦ1600/110-3×3W
WSGⅦ1600/110-4×5W
WSGⅦ1600/110-5×7W
|
110 |
250 |
440 |
WSGⅦ2000/35-3×3W
WSGⅦ2000/35-4×5W
WSGⅦ2000/35-5×7W
|
2000 |
35 |
340 |
275 |
260 |
1950 |
690 |
600 |
630 |
330 |
220 |
410 |
WSGⅦ△2000/35-3×3W
WSGⅦ△2000/35-4×5W
WSGⅦ△2000/35-5×7W
|
注:1、开关的相别由用户定.
|